1.
Rev. Assoc. Med. Bras. (1992, Impr.) ; 68(11): 1582-1586, Nov. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1406592

RESUMO

SUMMARY OBJECTIVE: This study aimed to assess the perinatal outcomes of pregnancies with a prenatal diagnosis of congenital cystic adenomatoid malformation. METHODS: We conducted a retrospective cohort study based on information contained in the medical records of pregnant women whose fetuses had been prenatally diagnosed with congenital cystic adenomatoid malformation by ultrasonography. RESULTS: Sample analysis was based on 21 singleton pregnancies with confirmed isolated fetal congenital cystic adenomatoid malformations. The mean maternal±standard deviation age was 28±7.7 years. Types I, II, and III congenital cystic adenomatoid malformation were detected in 19% (4/21), 52.4% (11/21), and 28.6% (6/21), respectively. All fetuses presented with unilateral congenital cystic adenomatoid malformation (21/21) without associated anomalies, and 52.3% (11/21) were in the right lung. In total, 33.3% (7/21) of fetuses presented a "congenital cystic adenomatoid malformation volume ratio" >1.6 and were managed with maternal betamethasone administration. The mean gestational age at the time of steroid administration was 28.5±0.9 weeks, with a reduction in the lesion dimensions of 9.5% (2/21) (Types I and III of congenital cystic adenomatoid malformation). The mean gestational age at delivery was 38.7±2.4 weeks, and a cesarean section was performed in 76.2% (16/21) cases. Postsurgical resection was necessary for 23.8% (5/21) of the patients, and 4.7% (1/21) of them died because of respiratory complications after surgery. Pulmonary hypoplasia occurred in 9.5% (2/21) of the patients, and 4.7% (1/21) of them died because of respiratory insufficiency. The survival rate was 90.5% (19/21), and 57.2% (12/21) remained asymptomatic. CONCLUSION: Despite the isolated prenatal diagnosis of congenital cystic adenomatoid malformation, which showed good survival, congenital cystic adenomatoid malformation is associated with significant perinatal morbidity. Maternal betamethasone administration did not significantly reduce fetal lung lesion dimensions.

4.
Rev. bras. cir. cardiovasc ; 27(2): 275-282, abr.-jun. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-649604

RESUMO

OBJETIVO: Comparar do débito cardíaco (DC) e a fração de ejeção (FE) do coração de fetos masculinos e femininos obtidos por meio da ultrassonografia tridimensional, utilizando o spatio-temporal image correlation (STIC). MÉTODOS: Realizou-se um estudo de corte transversal com 216 fetos normais, entre 20 a 34 semanas de gestação, sendo 108 masculinos e 108 femininos. Os volumes ventriculares no final da sístole e diástole foram obtidos por meio do STIC, sendo as avaliações volumétricas realizadas pelo virtual organ computer-aided analysis (VOCAL) com rotação de 30º. Para o cálculo do DC utilizou-se a fórmula: DC= volume sistólico/frequência cardíaca fetal, enquanto que para a FE utilizou-se a fórmula: FE= volume sistólico/volume diastólico final. O DC (combinado, feminino e masculino) e a FE (masculina e feminina) foram comparadas utilizando-se o teste t não pareado e ANCOVA. Foram criados gráficos de dispersão com os percentis 5, 50 e 95. RESULTADOS: A média do DC combinado, DC direito, DC esquerdo, FE direita e FE esquerda, para feminino e masculino, foram 240,07 mL/min; 122,67 mL/min; 123,40 mL/min; 72,84%; 67,22%; 270,56 mL/min; 139,22 mL/min; 131,34 mL/min; 70,73% e 64,76%, respectivamente; sem diferença estatística (P> 0,05). CONCLUSÕES: O DC e a FE fetal obtidos por meio da ultrassonografia tridimensional (STIC) não apresentaram diferença significativa em relação ao gênero.


OBJECTIVE: To compare the cardiac output (CO) and ejection fraction (EF) of the heart of male and female fetuses obtained by 3D-ultrasonography using spatio-temporal image correlation (STIC). METHODS: We conducted a cross-sectional study with 216 normal fetuses, between 20 and 34 weeks of gestation, 108 male and 108 female. Ventricular volumes at the end of systole and diastole were obtained by STIC, and the volumetric assessments performed by the virtual organ computer-aided analysis (VOCAL) rotated 30º. To calculate the DC used the formula: DC = stroke volume / fetal heart rate, while for the FE used the formula: EF = stroke volume / end-diastolic volume. The DC (combined male and female) and EF (male and female) were compared using the unpaired t test and ANCOVA. Scatter plots were created with the percentiles 5, 50 and 95. RESULTS: The average of DC combined, DC left, DC right, FE right and FE left, male and female were 240.07 mL/min, 122.67 mL/min, 123.40 mL/min, 72.84%, 67.22%, 270.56 mL/ min, 139.22 mL/min, 131.34 mL/min, 70.73% and 64.76% respectively, without statistical difference (P> 0.05). CONCLUSIONS: The fetal CO and EF obtained by 3Dultrasonography (STIC) showed no significant difference in relation to gender.


Assuntos
Feminino , Humanos , Masculino , Débito Cardíaco/fisiologia , Coração Fetal , Volume Sistólico/fisiologia , Ultrassonografia Pré-Natal/métodos , Ecocardiografia Tridimensional/métodos , Idade Gestacional , Processamento de Imagem Assistida por Computador/métodos , Valores de Referência , Fatores Sexuais , Análise Espaço-Temporal , Fatores de Tempo
5.
Arq. bras. cardiol ; 96(5): 386-392, maio 2011.
Artigo em Português | LILACS | ID: lil-587645

RESUMO

FUNDAMENTO: A detecção precoce de alterações septais, tais como a hipertrofia septal comumente presente em fetos de mães diabéticas, contribuiria para a redução das altas taxas de mortalidade infantil. OBJETIVO: Determinar intervalos de referência para a área do septo interventricular fetal por meio da ultrassonografia tridimensional (US3D) utilizando o método STIC (Spatio-Temporal Image Correlation). MÉTODOS: Realizou-se um estudo de corte transversal com 69 gestantes normais entre a 18ª e 33ª semanas de gestação. Utilizou-se como referência o plano de quatro câmaras com a ROI (Região de Interesse) posicionada a partir dos ventrículos, sendo a área do septo delimitada de modo manual. Para se avaliar a correlação da área do septo interventricular com a idade gestacional (IG), construíram-se diagramas de dispersão e calculou-se o coeficiente de correlação de Pearson (r), sendo o ajuste realizado pelo coeficiente de determinação (R²). Foram calculadas médias, medianas, desvios-padrão (dp), valores máximo e mínimo. Para o cálculo da reprodutibilidade intraobservador, utilizou-se o coeficiente de correlação intraclasse (CCI). Obteve-se a medida da espessura do septo interventricular e ela foi correlacionada com a IG e a área septal obtida pelo modo renderizado em 52 pacientes utilizando-se o CCI. RESULTADOS: A área do septo interventricular foi altamente correlacionada com a idade gestacional (r = 0,81), e a média aumentou de 0,47 cm² na 18ª para 2,42 cm² na 33ª semana de gestação. A reprodutibilidade intraobservador foi excelente com CCI = 0,994. Não se observou correlação significativa entre a medida do septo interventricular e a IG (R² = 0,200), assim como não houve correlação com a área do septo obtida pelo modo renderizado com CCI = 0,150. CONCLUSÃO: Intervalos de referência para a área do septo interventricular entre a 18ª e 33ª semanas de gestação foram determinados e se mostraram altamente reprodutíveis.


BACKGROUND: Early detection of septal changes such as septal hypertrophy commonly present in fetuses of diabetic mothers would help reduce the high rates of infant mortality. OBJECTIVE: Determine reference ranges for the fetal ventricular septal area through three-dimensional ultrasound (US3D) using the STIC method (Spatio-Temporal Image Correlation). METHODS: We conducted a cross-sectional study with 69 pregnant women between the 18th and 33rd weeks of pregnancy. We used as a reference the four-chamber plane with the ROI (Region of Interest) positioned from the ventricles; the septum area were manually marked. To assess the correlation of the interventricular septum area with gestational age (GA), we constructed scatter plots and calculated Pearson's correlation coefficient (r), and the adjustment was performed by the coefficient of determination (R²). We calculated averages, medians, standard deviations (sd), as well as maximum and minimum values. To calculate the intraobserver reproducibility, we used the intraclass correlation coefficient (ICC). The interventricular septum thickness was measured and it was correlated with gestational age and the septal area rendered in 52 patients using the ICC. RESULTS: The interventricular septum area was highly correlated with gestational age (r = 0.81), and the average increased from 0.47 cm² in the 18th week to 2.42 cm² in the 33rd of gestation. The intraobserver reproducibility was excellent with ICC = 0.994. No significant correlation was observed between the interventricular septum measurement and the GA (R² = 0.200), as well as there was no correlation with the septal area rendered with ICC = 0.150. CONCLUSION: Reference intervals for the interventricular septum area between the 18th and the 33rd pregnancy week were determined to be highly reproducible.


FUNDAMENTO: La detección precoz de alteraciones septales, tales como la hipertrofia septal comúnmente presente en fetos de madres diabéticas, contribuiría a la reducción de las altas tasas de mortalidad infantil. OBJETIVO: Determinar intervalos de referencia para el área del septo interventricular fetal por medio de la ultrasonografía tridimensional (US3D) utilizando el método STIC (Spatio-Temporal Image Correlation). MÉTODOS: Se realizó un estudio de corte transversal con 69 gestantes normales entre la 18ª y 33ª semanas de gestación. Se utilizó como referencia el plano de cuatro cámaras con la ROI (Región de Interés) posicionada a partir de los ventrículos, siendo el área del septo delimitada de modo manual. Para evaluar la correlación del área del septo interventricular con la edad gestacional (EG), se construyeron diagramas de dispersión y se calculó el coeficiente de correlación de Pearson (r), siendo el ajuste realizado por el coeficiente de determinación (R²). Fueron calculadas medias, medianas, desviaciones-estándar (de), valores máximo y mínimo. Para el cálculo de la reproductibilidad intraobservador, se utilizó el coeficiente de correlación intraclase (CCI). Se obtuvo la medida del espesor del septo interventricular y la misma fue correlacionada con la EG y el área septal obtenida por el modo renderizado en 52 pacientes utilizando el CCI. RESULTADOS: El área del septo interventricular fue altamente correlacionada con la edad gestacional (r = 0,81), y la media aumentó de 0,47 cm² en la 18ª a 2,42 cm² en la 33ª semana de gestación. La reproductibilidad intraobservador fue excelente con CCI = 0,994. No se observó correlación significativa entre la medida del septo interventricular y la EG (R² = 0,200), así como no hubo correlación con el área del septo obtenida por el modo renderizado con CCI = 0,150. CONCLUSIÓN: Intervalos de referencia para el área del septo interventricular entre la 18ª y 33ª semanas de gestación fueron determinados ...


Assuntos
Adulto , Feminino , Humanos , Gravidez , Coração Fetal , Idade Gestacional , Imageamento Tridimensional/métodos , Ultrassonografia Pré-Natal/métodos , Septo Interventricular , Estudos Transversais , Variações Dependentes do Observador , Segundo Trimestre da Gravidez/fisiologia , Terceiro Trimestre da Gravidez/fisiologia , Valores de Referência , Reprodutibilidade dos Testes
6.
Radiol. bras ; 43(6): 369-374, nov.-dez. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-571675

RESUMO

OBJETIVO: Avaliar a reprodutibilidade intra e interobservador do Doppler de amplitude tridimensional (3D power Doppler) na avaliação do fluxo sanguíneo cerebral do território da artéria cerebral média. MATERIAIS E MÉTODOS: Foi realizado estudo transversal com 20 gestantes normais entre 26 e 34 semanas. O território da artéria cerebral média mais próximo ao transdutor foi selecionado e o volume foi calculado utilizando-se o método Virtual Organ Computer-aided AnaLysis. Posteriormente, obtiveram-se os índices do 3D power Doppler: índice de vascularização (VI), índice de fluxo (FI) e índice de vascularização-fluxo (VFI). Utilizaram-se, para os cálculos, o coeficiente de correlação intraclasse (CCI) e gráficos de Bland-Altman. RESULTADOS: Foi observada boa concordância intra e interobservador, com CCI > 0,90 para todos os índices do 3D power Doppler: VI [CCI = 0,992 (IC 95 por cento: 0,981-0,997)], FI [CCI = 0,999 (IC 95 por cento: 0,998-0,999)], VFI [CCI = 0,995 (IC 95 por cento: 0,987-0,998)]. Reprodutibilidade interobservador: VI [CCI = 0,988 (IC 95 por cento: 0,970-0,995)], FI [CCI = 0,999 (IC 95 por cento: 0,997-1,000)], VFI [CCI = 0,994 (IC 95 por cento: 0,994-0,998)]. CONCLUSÃO: O 3D power Doppler mostrou-se um método prático, fácil e com boa reprodutibilidade intra e interobservador, com o IF evidenciando a melhor concordância intra e interobservador.


OBJECTIVE: To evaluate the intra- and interobserver reproducibility of three-dimensional power Doppler sonography (3D power Doppler) in the assessment of fetal brain blood flow in the middle cerebral artery territory. MATERIALS AND METHODS: A cross-sectional study was developed with 20 healthy pregnant women between 26 and 34 gestational weeks. The middle cerebral artery territory closest to the transducer was scanned and the blood flow volume was calculated with the method Virtual Organ Computer-aided AnaLysis. The following 3D power Doppler indices were later obtained: vascularization index (VI), flow index (FI) and vascularization-flow index (VFI). The intraclass correlation coefficient (ICC) and Bland-Altman plots were utilized for calculating the intra- and interobserver variability. RESULTS: A good intra- and interobserver agreement was observed, with ICC > 0.90 for all the 3D power Doppler indices: VI [ICC = 0.992 (CI 95 percent: 0.981-0.997)], FI [ICC = 0.999 (CI 95 percent: 0.998-0.999)], VFI [ICC = 0.995 (CI 95 percent: 0.987-0.998)]. Interobserver reproducibility: VI [ICC = 0.988 (CI 95 percent: 0.970-0.995)], FI [ICC = 0.999 (CI 95 percent: 0.997- 1.000)], VFI [ICC = 0.994 (CI 95 percent: 0.994-0.998)]. CONCLUSION: 3D power Doppler has shown to be a practical and easy method in the assessment of fetal brain blood flow, with good intra- and interobserver reproducibility. The FI presented the best intra- and interobserver agreement.


Assuntos
Humanos , Feminino , Gravidez , Fluxo Sanguíneo Regional/fisiologia , Artéria Cerebral Média , Reprodutibilidade dos Testes , Círculo Arterial do Cérebro , Desenvolvimento Fetal , Ultrassonografia Pré-Natal
7.
Rev. bras. ginecol. obstet ; 32(12): 573-578, dez. 2010. graf, tab
Artigo em Português | LILACS | ID: lil-581579

RESUMO

OBJETIVO: determinar os valores de referência para o comprimento e a área do corpo caloso fetal entre a 20ª e 33ª semanas de gestação por meio da ultrassonografia tridimensional (US3D). MÉTODOS: foi realizado um estudo do tipo corte transversal com 70 gestantes normais entre a 20ª e 33ª semanas de gestação. Utilizou-se um aparelho da marca Accuvix XQ, equipado com transdutor convexo volumétrico (3 a 5 MHz). Para a obtenção do corpo caloso fetal, foi utilizado um plano transfrontal, com a sutura metópica como janela acústica. Para o cálculo do comprimento, utilizou-se a distância entre os pontos médios dos polos proximal e distal do corpo caloso. Para o cálculo da área, a delimitação manual da superfície externa do corpo caloso foi realizada. Para o comprimento e a área do corpo caloso, foram calculadas: as médias, as medianas, os desvios padrão e os valores máximo e mínimo. Para a correlação da área e do comprimento do corpo caloso com a idade gestacional e o diâmetro biparietal foram criados diagramas de dispersão, sendo a qualidade dos ajustes verificada pelo coeficiente de determinação (R²). Para a variabilidade intraobservador, utilizou-se o coeficiente de correlação intraclasse (CCI). RESULTADOS: a média do comprimento do corpo caloso variou de 21,7 mm (18,6 - 25,2 mm) a 38,7 mm (32,6 - 43,3 mm) entre a 20ªe 33ª semanas, respectivamente. A média da área do corpo caloso variou de 55,2 mm² (41,0 - 80,0 mm²) a 142,2 mm² (114,0 - 160,0 mm²) entre a 20ªe 33ª semanas, respectivamente. O comprimento e a área do corpo caloso foram fortemente correlacionados com a idade gestacional (R² = 0,7 e 0,7, respectivamente) e com o diâmetro biparietal (R² = 0,7 e 0,6, respectivamente). A variabilidade intraobservador foi adequada com CCI = 0,9 e 0,9 para o comprimento e área, respectivamente. CONCLUSÕES: valores de referência para o comprimento e área do corpo caloso fetal entre a 20ªe 33ª semanas foram determinados. A variabilidade intraobservador foi adequada.


PURPOSE: to establish reference values for the length and area of the fetal corpus callosum between the 20th and 33rd weeks of gestation using three-dimensional ultrasound (3DUS). METHODS: this cross-sectional study involved 70 normal pregnancies with gestational age between 20 and 33 weeks. An Accuvix XQ instrument with a convex volumetric transducer (3 to 5 MHz) was used. To assess the corpus callosum, a transfrontal plane was obtained using the metopic suture as an acoustic window. Length was obtained by measuring the distance between the proximal and distal extremities of the corpus callosum. Area was obtained by manual tracing of the external corpus callosum surface. The means, medians, standard deviations, and maximum and minimum values were calculated for the corpus callosum length and area. Scatter graphs were created to analyze the correlation between corpus callosum length and area and gestational age and biparietal diameter, the quality adjustments was verified according to the determination coefficient (R²). The intraclass correlation coefficient (ICC) was used to assess the intraobserver variability. RESULTS: mean corpus callosum length increased from 21.7 (18.6 - 25.2 mm) to 38.7 mm (32.6 - 43.3 mm) between 20 and 33 weeks of pregnancy, respectively. Mean corpus callosum area increased from 55.2 (41.0 - 80.0 mm²) to 142.2 mm² (114.0 - 160.0 mm²), between 20 to 33 weeks of pregnancy, respectively. There was a strong correlation between corpus callosum length and area and gestational age (R² = 0.7 and 0.7, respectively) and biparietal diameter (R² = 0.7 and 0.6, respectively). Intraobserver variability was appropriate, with an ICC of 0.9 and 0.9 for length and area, respectively. CONCLUSIONS: reference values for corpus callosum length and area were established for fetuses between 20 and 33 weeks gestation. Intraobserver variability was appropriate.


Assuntos
Feminino , Humanos , Gravidez , Corpo Caloso/embriologia , Corpo Caloso , Ecoencefalografia , Imageamento Tridimensional , Ultrassonografia Pré-Natal , Estudos Transversais , Idade Gestacional , Tamanho do Órgão , Valores de Referência
8.
Rev. bras. ginecol. obstet ; 32(9): 426-432, set. 2010. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-572646

RESUMO

OBJETIVO: avaliar as áreas das válvulas atrioventriculares (tricúspide e mitral) de fetos normais por meio da ultrassonografia tridimensional (US3D) utilizando o método STIC (spatiotemporal image correlation). MÉTODOS: realizou-se estudo de corte transversal com 141 mulheres entre a 18ª e a 33ª semana de gestação. As medidas dos volumes cardíacos foram obtidas por um transdutor volumétrico transabdominal acoplado ao aparelho Voluson 730 Expert. Utilizou-se como referência o plano de quatro câmaras com a ROI (região de interesse) posicionada a partir dos ventrículos, sendo a área das valvas delimitada manualmente. Para conhecer a correlação das áreas valvulares com a idade gestacional, foram construídos diagramas de dispersão e calculou-se o coeficiente de correlação de Pearson (r). Foram calculadas médias, medianas, desvios padrão (DP), valores máximo e mínimo. Para se determinar intervalos de referência das áreas valvulares em função da idade gestacional, seguiu-se o modelo de regressão linear simples, utilizando o método de Altman, com nível de significância de p<0,05. Para o cálculo da reprodutibilidade intraobservador, utilizou-se o coeficiente de correlação intraclasse (CCI) e o gráfico de Bland-Altman. RESULTADOS: as áreas valvulares tricúspide e mitral se correlacionaram com a idade gestacional (r=0,80 para a tricúspide e r=0,79 para a mitral), sendo que a média aumentou da válvula tricúspide e mitral, respectivamente, de 0,22±0,10 cm² e de 0,23±0,10 cm² na 18º semana para 0,92±0,29 cm² e para 1,08±0,41 cm² na 33º semana de gestação. A reprodutibilidade intraobservador resultou em CCI=0,993 (IC95 por cento 0,987; 0,996), com diferença média de 0,01 cm² (DP±0,2 cm² e IC95 por cento±0,4 cm²). CONCLUSÃO: intervalos de referência para a área das valvares mitral e tricúspide entre a 18ªe a 33ª semana de gestação foram determinados pela US3D e se mostraram altamente reprodutíveis.


PURPOSE: to evaluate the areas of the atrioventricular valves (tricuspid and mitral) of normal fetuses by the use of three-dimensional ultrasound (3DUS) and the spatiotemporal image correlation (STIC) method. METHODS: a cross-sectional study was conducted on 141 women between the 18th and the 33rd week of pregnancy. Cardiac volumes were measured with a volumetric transabdominal transducer attached to the Voluson 730 Expert equipment. The four chamber plane was used as reference, with the region of interest (ROI) positioned from the ventricles, and the area of the valves was obtained manually. To determine the correlation of the areas with gestational age, scatter plots were constructed and the Pearson correlation coefficient (r) was calculated. Means, medians, standard deviations (SD) and maximum and minimum values were calculated. The simple linear regression model was used to determine reference ranges of valve areas according to the gestational age by the Altman method, with the level of significance set at p<0.05. To calculate the intraobserver reproducibility, we used the intraclass correlation coefficient (ICC) and the Bland-Altman graph. RESULTS: the mitral and tricuspid valve areas were correlated to the gestational age (r=0.80 for the tricuspid and r=0.79 for the mitral valve) and the mean value of the tricuspid and mitral valves increased from 0.22±0.10 cm² and 0.23±0.10 cm² on the 18th week to 0.92±0.29 cm² and 1.08±0.41 cm² on the 33rd of pregnancy, respectively. The intraobserver reproducibility resulted in an ICC=0.993 (95 percentCI 0.987; 0.996) and the mean difference was 0.01 cm² (SD±0.2 cm² and CI95 percent±0.4 cm²). CONCLUSION: reference intervals for the areas of the mitral and tricuspid valve between the 18th and the 33rd week of gestation were determined and proved to be highly reproducible.


Assuntos
Adolescente , Adulto , Feminino , Humanos , Gravidez , Adulto Jovem , Imageamento Tridimensional , Valva Mitral/embriologia , Valva Mitral , Valva Tricúspide/embriologia , Valva Tricúspide , Ultrassonografia Pré-Natal , Estudos Transversais , Valores de Referência
9.
Radiol. bras ; 43(4): 219-223, jul.-ago. 2010. ilus
Artigo em Português | LILACS | ID: lil-557973

RESUMO

OBJETIVO: Avaliar a reprodutibilidade do volume do braço e coxa fetais aferido pela ultrassonografia tridimensional utilizando o método eXtended Imaging Virtual Organ Computer-aided AnaLysis (XI VOCAL). MATERIAIS E MÉTODOS: Realizou-se estudo de reprodutibilidade com 43 fetos normais entre 20 e 37 semanas. Para o cálculo do volume do braço e coxa fetais utilizou-se o método XI VOCAL com delimitação de 10 planos consecutivos. Para o cálculo da variabilidade interobservador, um examinador realizou uma medida do volume do braço e coxa dos 43 fetos, enquanto um segundo examinador, sem o conhecimento prévio dos resultados do primeiro examinador, realizou uma segunda medida dos mesmos volumes. Utilizaram-se, para os cálculos estatísticos, o coeficiente de correlação intraclasse (ricc), gráficos de Bland-Altman e teste t-Student pareado (p). RESULTADOS: Observou-se alta reprodutibilidade interobservador. Para o volume do braço, obtiveram-se ricc = 0,996 (intervalo de confiança [IC] 95 por cento: 0,992; 0,998) e média das diferenças = 0,13 ± 1,29 por cento (95 por cento limites de concordância: -2,54; +2,54 por cento). Para o volume da coxa, obtiveram-se ricc = 0,997 (IC 95 por cento: 0,995; 0,999) e média das diferenças = 0,24 ± 7,60 por cento (95 por cento limites de concordância: -7,6; +7,6 por cento). CONCLUSÃO: O volume do braço e coxa fetais aferido pela ultrassonografia tridimensional utilizando o método XI VOCAL apresentou elevada reprodutibilidade interobservador.


OBJECTIVE: To assess the reproducibility of fetal thigh and upper arm volumes measurement by threedimensional ultrasonography utilizing the eXtended Imaging Virtual Organ Computer-aided AnaLysis (XI VOCAL) method. MATERIALS AND METHODS: This reproducibility study enrolled 43 pregnant women with healthy singleton pregnancies between 20 and 37 gestational weeks. The XI VOCAL 10 planes was the method utilized for volumetric measurement of the fetal limbs. The calculation of the interobserver reproducibility was based on blind volumetric measurements of fetal thighs and upper-arms performed by two observers in 43 fetuses. Intraclass correlation coefficient (ICC), Bland-Altman plots and paired Student's t-test (p) were utilized in the statistical analysis. RESULTS: A high interobserver reproducibility was observed. For the upper arm volume ICC was 0.996 (confidence interval [CI] 95 percent: 0.992; 0.998) and mean difference = 0.13 ± 1.29 percent (95 percent limits of agreement: -2.54; +2.54 percent). For the thigh volume, ICC was 0.997 (CI 95 percent: 0.995; 0.999) and mean difference = 0.24 ± 7.60 percent (95 percent limits of agreement: -7.6; +7.6 percent). CONCLUSION: Fetal thigh and upper arm volumes measured by three-dimensional ultrasonography with the XI VOCAL method presented a high interobserver reproducibility.


Assuntos
Humanos , Feminino , Gravidez , Adulto , Braço , Braço/anatomia & histologia , Braço/crescimento & desenvolvimento , Quadril/anatomia & histologia , Extremidades/anatomia & histologia , Extremidades/crescimento & desenvolvimento , Desenvolvimento Fetal , Sensibilidade e Especificidade , Braço , Quadril , Imageamento Tridimensional , Tamanho do Órgão , Reprodutibilidade dos Testes
10.
Radiol. bras ; 43(3): 143-148, maio-jun. 2010. ilus, graf
Artigo em Inglês, Português | LILACS | ID: lil-552314

RESUMO

OBJETIVO: Avaliar a reprodutibilidade interobservador dos índices de vascularização do Doppler de amplitude tridimensional (Doppler de amplitude 3D) no primeiro trimestre de gestação. MATERIAIS E MÉTODOS: Realizou-se estudo de reprodutibilidade com 32 gestantes normais entre 7 e 10 semanas e 6 dias. Para o cálculo do volume tridimensional dos embriões utilizou-se o método VOCAL (Virtual Organ Computer-aided AnaLysis) com ângulo de rotação de 12°. Em seguida obtiveram-se, automaticamente, os três índices vasculares do Doppler de amplitude 3D: índice de vascularização (VI), índice de fluxo (FI) e índice de vascularização e fluxo (VFI). Para o cálculo da variabilidade interobservador, um examinador realizou uma segunda medida dos 32 embriões e um segundo examinador realizou uma terceira medida dos mesmos volumes, ambos desconhecendo os resultados do outro. Utilizaram-se, para análise estatística, o coeficiente de correlação intraclasse (CCI) e gráficos de Bland-Altman. RESULTADOS: Observou-se boa reprodutibilidade interobservador dos três índices vasculares. O VI apresentou CCI = 0,9 e média da diferença = -1,1; o FI apresentou CCI = 0,9 e média da diferença = -0,5; e o VFI apresentou CCI = 0,9 e média da diferença = -1,1. CONCLUSÃO: Os índices vasculares do Doppler de amplitude 3D do embrião no primeiro trimestre de gestação foram altamente reprodutíveis, em especial o FI.


OBJECTIVE: To evaluate the interobserver reproducibility of vascular indices obtained with three-dimensional power Doppler (3D power Doppler) ultrasonography at the first trimester of gestation. MATERIALS AND METHODS: The present reproducibility study involved 32 healthy pregnant women with 7 to 10 weeks and 6 days of gestation. The VOCAL (Virtual Organ Computer-aided AnaLysis) method was utilized to calculate embryos volume, with a 12° rotational angle. Subsequently, the software automatically displayed three 3D power Doppler vascular indices: vascularization index (VI), flow index (FI) and vascularization and flow index (VFI). In order to calculate the interobserver variability, an investigator performed a second blind measurement of the 32 embryos, and another investigator performed a third blind measurement of the same volumes. The interclass correlation coefficient (ICC) and Bland-Altman plots were utilized for statistical analysis. RESULTS: A good interobserver reproducibility was observed in relation to the three vascular indices. The VI presented ICC = 0.9 and mean difference between measurements = -1.1. For the FI, the ICC was 0.9 and mean difference = -0.5. The VFI presented ICC = 0.9 and mean difference = -1.1. CONCLUSION: The vascular indices, particularly the FI, obtained with 3D power Doppler ultrasonography at the first trimester of gestation demonstrated a high reproducibility.


Assuntos
Humanos , Feminino , Gravidez , Imageamento Tridimensional , Primeiro Trimestre da Gravidez , Reprodutibilidade dos Testes , Gestantes , Ultrassonografia Doppler
11.
Radiol. bras ; 43(2): 81-84, mar.-abr. 2010. ilus, graf, tab
Artigo em Inglês, Português | LILACS | ID: lil-551813

RESUMO

OBJETIVO: Determinar valores de referência para o volume da placenta entre 7 e 10 semanas e 6 dias de gestação por meio da ultrassonografia tridimensional utilizando o método XI VOCAL (eXtended Imaging Virtual Organ Computer-aided Analysis). MATERIAIS E MÉTODOS: Realizou-se estudo de corte transversal com 70 gestantes normais entre 7 e 10 semanas e 6 dias. Para o cálculo de volume, utilizou-se o método XI VOCAL com delimitação de dez planos adjacentes. Foram determinadas médias, medianas, desvios-padrão, valores máximo e mínimo para o volume da placenta. Para avaliar a correlação do volume da placenta com a idade gestacional, foi criado gráfico de dispersão, sendo o ajuste realizado pelo coeficiente de determinação (R²). RESULTADOS: A média do volume da placenta variou de 4,6 cm³ (2,6-8,6 cm³) a 28,9 cm³ (11,4-66,9 cm³). O volume da placenta (VP) se mostrou altamente correlacionado com a idade gestacional (IG), sendo o melhor ajuste com a regressão exponencial [VP = exp(0,582 × IG + 0,063); R² = 0,82]. CONCLUSÃO: Valores de referência para o volume da placenta no primeiro trimestre de gestação utilizando o método XI VOCAL foram determinados.


OBJECTIVE: To determine reference values for placental volume at 7 to 10 + 6 weeks of gestation by means of three-dimensional ultrasonography with the XI VOCAL (eXtended Imaging Virtual Organ Computer-aided Analysis) method. MATERIALS AND METHODS: A cross-sectional study was developed with 70 pregnant women at 7 to 10 + 6 weeks of gestation. The XI VOCAL method with ten sequential adjacent planes was utilized in the volume calculations. Means, medians, standard deviation, minimum and maximum values for placental volume were calculated. A scatter plot adjusted by the determination coefficient (R²) was constructed to correlate placental volume and gestational age. RESULTS: Mean placental volume ranged from 4.6 cm³ (2.6-8.6 cm³) to 28.9 cm³ (11.4-66.9 cm³). The placental volume (PV) has shown to be highly correlated with the gestational age (GA) and the best fit equation was [PV = exp(0.582 × GA + 0.063); R² = 0.82]. CONCLUSION: Reference values for placental volume in the first gestational trimester were determined with the XI VOCAL method.


Assuntos
Humanos , Feminino , Gravidez , Adulto Jovem , Idade Gestacional , Primeiro Trimestre da Gravidez , Placenta/anatomia & histologia , Tamanho do Órgão , Ultrassonografia/métodos
12.
Rev. Assoc. Med. Bras. (1992) ; 56(1): 99-102, 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-541168

RESUMO

OBJETIVO: Avaliar a cicatriz uterina pelo histograma escala-cinza (HEC) em gestantes primíparas com uma cesariana prévia, considerando quando esta foi realizada fora do trabalho de parto (cesárea eletiva) ou durante o trabalho de parto. MÉTODOS: Foi realizado estudo prospectivo em 40 gestantes, entre 11 e 14 semanas, que foram divididas em três grupos: 15 gestantes com uma cicatriz prévia resultante de cesariana eletiva (grupo A); 9 gestantes com uma cicatriz prévia oriunda de cesariana executada em trabalho de parto (grupo B); 16 gestantes cujo único parto anterior foi realizado por via vaginal (grupo C). As gestantes foram examinadas com ultrassonografia transvaginal, obtendo-se a imagem correspondente à sombra formada pela cicatriz uterina nos grupos A e B. No grupo C, optou-se por realizar o HEC na região do istmo uterino. Após a captura da imagem, foi delimitada a região de interesse (ROI) e ativada a opção histogram, obtendo-se automaticamente a sua representação gráfica. Foram calculadas as médias, medianas e desvios padrão (DP) para cada grupo em estudo. A média dos valores dos histogramas do grupo controle serviu como parâmetro de normalidade a ser comparado com os outros grupos. Para se comparar as médias dos três grupos, utilizou-se o teste de ANOVA. O valor de (p) < 0.05 foi considerado estatisticamente significante. RESULTADOS: O HEC do grupo A variou de 7 a 40,5 (média: 24,9 e DP: 11,2), no grupo B de 23,1 a 47,2 (média: 34,1 e DP: 9,6) e no grupo C de 21,6 a 58,8 (média: 40,3 e DP: 11,3). CONCLUSÃO: Houve significativa diferença do HEC na região da cicatriz uterina de cesárea prévia, quando esta foi realizada eletivamente e quando foi feita na vigência do trabalho de parto, sugerindo maior alteração tecidual na cesariana eletiva.


OBJECTIVE: To evaluate the Cesarean uterine scar by the grey-level histogram (GLH) in women with a previous Cesarean section, performed either during labor or before labor (elective Cesarean). METHODS: A prospective study was conducted with 40 women between 11 and 14 weeks of gestation, who were allocated to three groups: 15 pregnant women with a previous elective Cesarean (group A); 9 with a previous Cesarean section performed during labor (group B); and 16 with a single previous vaginal delivery (group C). The pregnant women were examined by transvaginal ultrasound, to obtain an image corresponding to the "shadow" formed by the uterine scar in groups A and B. In group C GLH was accomplished in the region of the uterine isthmus. After capture of the image, the region-of-interest (ROI) was delimited and the option "histogram" was activated, to automatically obtain graphic representation. The mean, median and standard deviation (SD) were calculated. for each group under study Mean values of the control group histograms were used as the normality parameter for comparison with the other groups. To compare averages of the three groups, the ANOVA test was used. A (p) value of < 0.05 was considered statistically significant. RESULTS: GLH in group A varied from 7.0 to 40.5 (mean: 24.9 and DP: 11.2), in group B from 23,1 to 47.2 (mean: 34,. and DP: 9.6) and in group C from 21.6 to 58.8 (mean: 40.3 and DP: 11.3). CONCLUSION: There was a significant difference of GLH in the region of the uterine scar of previous Cesareans, when it was elective and when performed during labor, suggesting a larger tissue change in the elective Cesarean.


Assuntos
Feminino , Humanos , Gravidez , Cesárea/efeitos adversos , Cicatriz , Estudos de Casos e Controles , Cicatriz/complicações , Procedimentos Cirúrgicos Eletivos , Endossonografia , Estudos Prospectivos
13.
Rev. Assoc. Med. Bras. (1992) ; 56(2): 204-208, 2010. graf, tab
Artigo em Português | LILACS | ID: lil-546940

RESUMO

OBJETIVO: Avaliar a acurácia de uma fórmula utilizando o volume do braço (VolBra), da coxa (VolCox) e parâmetros bidimensionais [circunferência abdominal (CA) e comprimento do fêmur (CF)] fetais na predição de peso ao nascimento. MÉTODOS: Realizou-se um estudo do tipo corte transversal envolvendo 78 gestações únicas de fetos vivos, euploides e sem malformações estruturais, dentro de 48 horas antes do nascimento. O VolBra e o VolCox foram aferidos por meio da ultrassonografia tridimensional utilizando-se o modo multiplanar a intervalos de 5 mm. A CA e o CF foram aferidos por meio da ultrassonografia bidimensional. Foram realizadas análises de regressão linear e polinomial para determinação da melhor fórmula para predizer o peso fetal com base no VolBra, VolCox, CA e CF. Os erros obtidos com essas fórmulas foram comparados com os obtidos com as fórmulas de Shepard e Hadlock por meio de ANOVA. RESULTADOS: A melhor fórmula que estimou o peso ao nascimento foi uma linear simples (Peso= -1486,1 + 60,5CA + 140,57CF + 16,6VolBra + 4,8VolCox), com R2= 0,932. O erro (E), erro absoluto (EA), erro percentual (EP) e erro percentual absoluto (EPA) da fórmula que utiliza os parâmetros bi e tridimensionais foram 0 g, 0,2 por cento, 112,2 g e 3,7 por cento, respectivamente. Em relação às fórmulas bidimensionais, a nova equação apresentou menores E, EA, EP e EPA que a fórmula de Shepard, e menores EA e EPA em relação à fórmula de Hadlock. CONCLUSÃO: A fórmula de predição de peso utilizando o VolBra, VolCox, CF e CA se mostrou superior às fórmulas que utilizam apenas parâmetros bidimensionais.


OBJECTIVE: Assess and compare accuracy of birth weight prediction using a combination of two-dimensional (abdominal circumference - AC and femur length - FL) and three-dimensional parameters (fetal arm -VolArm and thigh -VolTh volumes). METHODS: A cross sectional study was carried out involving 78 singleton, live, euploid fetuses without structural malformations born within 48 hours after ultrasonography. VolArm and VolTh were obtained by three-dimensional ultrasound using the multiplanar mode at 5 mm intervals. AC and FL were measured by two-dimensional ultrasound. Linear and polynomial regressions were calculated to determine the best formula to predict birth weight using VolArm, VolTh , CA and FL. ANOVA was used to compare errors in birth weight prediction using this formula and those obtained using the Shepard and Hadlock formulae. RESULTS: The best formula for prediction of birth weight was a simple linear regression (Weight = -1486.1 + 60.5AC + 140.57FL + 16.6VolArm + 4.8VolTh), R2= 0.932. The error (E), absolute error (AE), percent error (PE) and absolute percent error (APE) for this new formula were 0 g, 0.2 percent, 112.2 g and 3.7 percent. This new formula had smaller E, AE, PE and APE than the Shepard formula and smaller AE and APE than Hadlock´s formula. CONCLUSION: A formula using VolArm, VolTh, AC and FL was more accurate for prediction of birth weight than formulae using only two-dimensional parameters.


Assuntos
Adolescente , Adulto , Feminino , Humanos , Gravidez , Adulto Jovem , Peso ao Nascer , Imageamento Tridimensional , Ultrassonografia Pré-Natal/métodos , Braço , Estudos de Coortes , Estudos Transversais , Fêmur , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Coxa da Perna , Circunferência da Cintura
14.
Radiol. bras ; 42(6): 359-362, nov.-dez. 2009.
Artigo em Inglês, Português | LILACS | ID: lil-536416

RESUMO

OBJETIVO: Avaliar a correlação do volume da vesícula vitelínica aferida por meio da ultrassonografia tridimensional com a idade gestacional entre a 7ª e a 10ª semanas. MATERIAIS E MÉTODOS: Realizou-se um estudo do tipo corte transversal envolvendo 72 gestantes normais entre a 7ª e a 10ª semanas de gestação. Para o cálculo do volume da vesícula vitelínica, utilizou-se o método multiplanar com intervalo de 1,0 mm entre os planos. Para o volume da vesícula vitelínica foram determinadas médias, medianas, desvios-padrão e valores máximo e mínimo. Para avaliar a correlação entre o volume da vesícula vitelínica e a idade gestacional, foram criados modelos de regressão, sendo os ajustes realizados pelo coeficiente de determinação (R²). RESULTADOS: O volume da vesícula vitelínica (VV) mostrou-se fracamente correlacionado com a idade gestacional (IG), melhor representado pela regressão quadrática, representada pela equação: volume VV = 0,9757 - 0,2499 × IG + 0,0172 × IG² (R² = 0,234). O volume médio da vesícula vitelínica variou de 0,07 cm³ (0,02-0,11) a 0,20 cm³ (0,02-0,74) entre a 7ª e a 10ª semanas de gestação, com média de 0,11 cm³ (± 0,10 cm³). CONCLUSÃO: O volume da vesícula vitelínica correlacionou-se fracamente com a idade gestacional.


OBJECTIVE: To evaluate the correlation between the yolk sac volume measured by three-dimensional ultrasonography with gestational age at 7-10 weeks. MATERIALS AND METHODS: A cross-sectional study involving 72 healthy pregnant women at 7th-10th gestational weeks. The multiplanar method with 1.0 mm intervals was utilized. Regression models were constructed to analyze the correlation between yolk sac volume and gestational age, adjusted by the determination coefficient (R²). Mean, median, standard deviation, maximum and minimum values for yolk sac volume were calculated for each gestational age. RESULTS: A poor correlation was observed between yolk sac volume (YSV) and gestational age (GA). The quadratic regression was the model that best expressed this correlation: YSV = 0.9757 - 0.2499 × GA + 0.0172 × GA² (R² = 0.234). Mean yolk sac volume ranged from 0.07 cm³ (0.02-0.11) to 0.20 cm³ (0.02-0.74) between the 7th and 10th weeks (mean, 0.11 cm³, ± 0.10 cm³). CONCLUSION: There was a poor correlation between yolk sac volume and gestational age.


Assuntos
Humanos , Feminino , Gravidez , Idade Gestacional , Tamanho do Órgão , Primeiro Trimestre da Gravidez , Gestantes , Saco Gestacional , Imageamento Tridimensional , Ultrassonografia Pré-Natal